New
| Input Current | Input Power Connection | Required Service Panel Breaker | |
|---|---|---|---|
| Standard | 30A | One 40A branch circuit | 40A dual pole (non-GFCI type) |
| Power Select 24A | 24A | One 30A branch circuit | 30A dual pole (non-GFCI type) |
| Power Select 16A | 16A | One 20A branch circuit | 20A dual pole (non-GFCI type) |
| Wiring | 3-wire (L1, L2, Earth) | ||
| Station Power | 8W typical (standby), 15W maximum (operation) | ||
| Standard | 7.2kW (240VAC @ 30A) |
|---|---|
| Power Select 24A | 5.8kW (240VAC @ 30A) |
| Power Select 16A | 3.8kW (240VAC @ 16A) |
| Connector | SAE J1772 |
|---|---|
| Overhead Cable Management | Yes |
LCD Display | 5.7" Full Colour Resolution: 640x480 Frame Rate: 30 FPS UV Protected |
| Card Reader | ISO 15693 ISO 14443 NFC |
| Locking Holster | Yes |
| Ground Fault Detection | 20mA with auto retry |
|---|---|
| Open Safety Ground Detection | Continuously monitors presence of safety (green wire) ground connection |
| Plug-Out Detection | Power terminated per SAE J1772™ specifications |
| Power Measurement Accuracy | +/- 2% from 2% to full scale (32A) |
| Power Report/Store Interval | 15 minute, aligned to the hour |
| Local Area Network | 2.4 GHz Wi-Fi (802.11 b/g/n) |
| Wide Area Network | 3G GSM, 3G CDMA |
| Enclosing Rating | Type 3R per UL 50E |
|---|---|
| Safety Compliance | cUL certified for Canada; Complies with UL 2594, UL 2231-1, UL 2231-2, and NEC Article 625 |
| Surge Protection | 6kV @ 3000A. In geographic areas subject to frequent thunderstorms, supplemental surge protection at the service panel is recommended. |
| EMC Compliance | FCC Part 15 Class A |
| Operating Temperature | -30°C to +50°C |
| Storage Temperature | -30°C to +60°C |
| Non-Operating Temperature | -40°C to +60°C |
| Operating Humidity | Up to 85% @ +50°C non-condensing |
| Non-Operating Humidity | Up to 95% @ +50°C non-condensing |
| Terminal Block Temperature Rating | 105°C |
| Maximum Charging Station per 802.11 Radio Group | 10. Each station must be located within 150 feet “line of sight” of a gateway station. |